Analog way BSD830-AG User Manual Page 43

  • Download
  • Add to my manuals
  • Print
  • Page
    / 45
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 42
BROAD SCAN (HD/SDI) APPENDIX A / ANNEXE A
COMMAND RESPONSE
COMMAND DESCRIPTION
TYPE
VALUE /VALEUR
COMMANDE RÉPONSE DESCRIPTION DE LA COMMANDE MIN
MAX DESCRIPTION
STATUS COMMANDS / COMMANDES D’ETAT
IK
IK
Input sync type detection
Rd
0
3
0 = separate H & V
1 = Composite sync (TTL)
2 = SOG (Sync On Green)
3 = Composite sync (analog)
II
II
Interlaced signal detection.
Rd
0
1
0 = not interlaced 1 = interlaced
IO
IO
Status of the signal in comparison with
the input range frequency.
Rd
0
1
0 = in range 1 = out of range
IF
IF
Input format detection
Rd
0
25
0 = No signal 1= Wrong signal
4 = 640x480 5 = 480p
6 = 852x480 7 = 800x600
8 = 1280x720 9 = 720p
10 = 10274x768 11 = 1280x768
12 = 1366x768 13 = 1280x800
14 = 1280x960 15 = 1280x1024
16 = 1364x1024 17 = 1035i
18 = 1400x1050 19 = 1680x1050
20 = 1920x1080 21 = 1080i
22 = 1080sf 23 = 1080p
24 = 1600x1200 25 = 1920x1200
XF
XF
Status of the synchronized format
(genlock).
Rd
0
25
XA
XA
Status of the synchronization mode
Rd
0
3
0 = internal
1 = genlock
2 = frame lock
3 = wrong signal.
XT
XT
Frame frequency of the synchronized
signal (genlock) (in hundredth of Hz)
Rd
0
65535
CC
CC
Selected Input
Rd
1
2
1 = Source 2 = Frame
?
DEV
Device model
Rd
59
63
59 = BHD930-DG 60 = BHD930-AG
61 = BSD830-DG 62 = BSD830-AG
63 = BSC730
NOTE: Rd = Read only command / Commande de lecture. Rd/Wr = Read and write command / Commande de lecture et d'écriture.